Project: Las Cruces Municipal Court House
Las Cruces Municipal Court House
135 E. Griggs Ave
Las Cruces, NM 88001
Thermography Infrared Roof Survey Report
Building and Location: Las Cruces Municipal Court House, 135 E. Griggs Ave. Las Cruces, NM 88001
Roof Sections Surveyed: 3
Square Footage: Approximately 5,942 square feet
Survey Date: October 7, 2024
Roof Inspection Survey Time: 7:00 pm
Daytime Weather Conditions: Sunny and clear
Last Recordable Rainfall: Greater than 3 days
Weather Conditions at Survey Start Time: Clear.
Ambient Temperature at Survey Start Time: 86.0° F
Imager Used: 4THGENHYBRID INFRARED
Granulated Modified Bitumen Roof Construction
Analysis of Infrared Thermography Roof Survey
A total of approximately 5,942 sq. ft. were surveyed over the granulated modified bitumen roof system.
No areas of moisture infiltration were found within the roof system during the infrared roof survey, but
repairs are required in applicable areas.
Inspection complies with ASTM Standard C1153 – 10 “Standard Practice for Location of Wet Insulation in
Roof Systems Using Infrared Imaging”

Moisture Survey
Aerial photo and video

Ground photo and video

Live Feed

Drone Mapping
Our licensed professionals are ready to elevate your Project.
FAA Part 107 Certified Remote Pilot